Using primary stability to avoid multiple surgeries

implant placement primary stabilityBen White describes how he used excellent primary stability to allow simultaneous sinus graft and implant placement.

A 57-year-old female was referred to White Dental for the replacement of her missing upper left first and second molar teeth (UL6 and UL7) with dental implants. The patient had lost the UL7 several years previously and the UL6 a few months ago (Figure 1). She had not been wearing a partial denture and was struggling to eat on her left side. She was medically fit and well. 

We discussed the possibility of a partial denture; however, the patient was keen to have a fixed replacement. 

Treatment planning

A detailed clinical examination was undertaken. The patient presented with a moderately restored dentition and healthy periodontal status. There was some buccal bone loss present at the UL7 site (Figure 1). 

A cone beam computed tomography (CBCT) scan was taken of the upper left posterior region, to accurately assess the bone height and width, and the anatomy and position of the maxillary sinus (Figures 2 to 4). 

The scan revealed good bone width, but loss of height due to pneumatisation of the sinus. The bone height was measured as 5mm at the UL6 site and 6mm at the UL7 site. Following discussion with the patient, she opted for a simultaneous sinus graft (open) and implant placement. A diagnostic wax-up was prepared and a surgical guide constructed.

Simultaneous sinus graft and implant placement

A buccal flap was reflected, and buccal window prepared using using piezosurgery. The sinus lining was then elevated. Once elevated, the implant sites were prepared using the Axiom PX protocol, which results in minimum bone trauma and excellent primary stability, due to the thread design. 

Prior to placement of the implants, a Bio-Gide membrane was placed into the sinus and the cavity infilled with a 50/50 mix of small and large-granule Bio-Oss. 

Two Axiom PX BL (bone-level) implants were then placed (Figure 5) – a 4.6mm x 8mm at the UL6 site and a 4.6mm x 10mm implant at the UL7 site. I opted for bone-level implants in this case as it allowed the implants to be fully submerged during the healing phase.  

Following a four-month healing period, the implants were exposed and two 3mm healing abutments placed. Two weeks later, both conventional and digital impressions were taken, as it was part of a clinical follow up (Figures 6 and 7). 

The case was transmitted to Jon Dolding from Ceramic Designs for construction of the final crowns (Figures 8 to 11). 

Laboratory stages 

Jon opted for two 4mm x 1.5mm flexi bases using models printed by Simeda with an integral analogue (Figure 10). The design was sent to Anthogyr’s CAD/CAM team for production of full contour zirconia crowns. 

Following a rapid turnaround, the crowns were returned to Jon for final finishing and polishing (Figure 11). 

Two weeks later, the healing abutments were removed, the crowns fitted and the definitive screws tightened to 25Ncm using the hexagonal wrench (Figure 12). The occlusion was checked, PTFE tape placed into the access channel, then filled with flowable composite. 

One advantage of zirconia is that the access channel is almost invisible once filled with composite (Figures 13 and 14).

The patient was very happy with the final result and is now able to chew food on the left-hand side. She reported her preference for the digital impression over the conventional impression.   


This article first ran in Clinical Dentistry magazine. Subscribe to read the latest issue of Clinical Dentistry magazine here.

Favorite
Get the most out of your membership by subscribing to Dentistry CPD
  • Access 600+ hours of verified CPD courses
  • Includes all GDC recommended topics
  • Powerful CPD tracking tools included
Register for webinar
Share
Add to calendar